S=Fibre Stress in PSI (Mpa) upto Gr 'B' 60% for size
x-46
0.26
1.40
0.030
0.030
-
-
46,000
317
-
-
63,000
434
-
-
-
>2 3/8" Gr X-42 and above 75% of min
X-52
0.26
1.40
0.030
0.030
-
-
52,000
359
-
-
66,000
455
-
-
-
size > 5-9/16 and <= 8-5/8
X-56
0.26
1.40
0.030
0.030
-
-
56,000
386
-
-
71,000
490
-
-
-
=85% Min Y.S for size > 8-5/8< 20 °
X-60
0.26
1.40
0.030
0.030
-
-
60,000
414
-
-
75,000
517
-
-
-
X-65
0.26
1.45
0.030
0.030
-
-
65,000
448
-
-
77,000
531
-
-
-
=90% Min Y.S for size > 20 °
X-70
0.26
1.65
0.030
0.030
-
-
70,000
483
-
-
82,000
565
-
-
-
STD Test Pressure for Gr 'X-42' & above limited to 3000 PSI
API 5L
ERW
B
0.22
1.20
0.025
0.015
0.25
0.43
35,000
241
65,000
448
60,000
414
110,000
758
T/L T/L
(20700 Gpa)
PSL-2
X-42
0.22
1.30
0.025
0.015
0.25
0.43
35,000
241
65,000
448
60,000
414
110,000
758
27/41 20/30
ALT Test Pressure limited to 7260 PSI(50000 kpa)
X-46
0.22
1.40
0.025
0.015
0.25
0.43
46,000
317
76,000
524
63,000
434
110,000
758
-d0-
X-52
0.22
1.40
0.025
0.015
0.25
0.43
52,000
359
77,000
531
66,000
455
110,000
758
-d0-
For size < 16" & 3630 PSI(25000 kpa.) for size >= 16"
X-56
0.22
1.40
0.025
0.015
0.25
0.43
56,000
386
79,000
544
71,000
490
110,000
758
-d0-
X-60
0.22
1.40
0.025
0.015
0.25
0.43
60,000
414
82,000
565
75,000
517
110,000
758
-d0-
X-65
0.22
1.45
0.025
0.015
0.25
0.43
65,000
448
87,000
600
77,000
531
110,000
758
-d0-
X-70
0.22
1.65
0.025
0.015
0.25
0.43
70,000
483
90,000
621
82,000
565
110,000
758
-d0-
IS:1978
ERW
YST-210
0.22
0.90
0.040
0.050
-
-
-
210
-
-
-
330
-
-
e=1942.57 A°.2/U °.9
L=longtitudinal T=Transverse
P=2000 ST/D (Limited to 19.3 Mpa)
YST-240
0.27
1.15
0.040
0.050
-
-
-
240
-
-
-
410
-
-
S=YST 210=124 for std pressure YST 240=145 for std pressure, 181 for ALT Pressure
IS:1979
ERW
YST-290
0.28
1.25
0.040
0.050
-
-
-
290
-
-
-
410
-
-
e=1942.57 A°.2/U°.9
YST-320
0.30
1.35
0.040
0.050
-
-
-
320
-
-
-
430
-
-
-
P=20000ST/D or 20700 kpa whichever smaller
YST-360
0.30
1.35
0.040
0.050
-
-
-
360
-
-
-
450*/500**
-
-
-
S=Fibre stress equal to specified minimum Y.S.
YST-390
0.26
1.35
0.040
0.050
-
-
-
390
-
-
-
490*/520**
-
-
-
YST-410
0.26
1.35
0.040
0.050
-
-
-
410
-
-
-
520*/540**
-
-
-
YST-450
0.26
1.40
0.040
0.050
-
-
-
450
-
-
-
530*/550**
-
-
-
Pipe size 168.3 to 219.1 mm OD=75%
YST-480
0.26
1.60
0.040
0.050
-
-
-
480
-
-
-
565
-
-
-
273.0 to 457.2 mm OD=85%
* Applicable for pipes with < 508mm OD and wall thickness, and pipe with 508mm OD and larger, and wall thickness > 9.5mm
** Applicable for pipes with 508mm OD and larger wall thickness <=9.5mm
508mm OD & large=90%
ASTM
ERW
A
0.25
0.95
0.050
0.045
-
-
30,000
205
-
-
48,000
330
-
-
e=625,000 A °.2/U°.9
P=2ST/D or 2800 PS1(19.3 Mpa)whichever smaller
A-53
B
0.30
1.20
0.050
0.045
-
-
35,000
240
-
-
60,000
415
-
-
S=0.60 times min.specified Y.S PS1(Kpa)
IS:3589
ERW
Fe330
0.16
1.20
0.040
0.040
-
-
-
195
-
-
-
330
-
-
G.L.=5.65√area 20
P=2ST/D shall not exceed Mpa
Fe410
0.20
1.30
0.040
0.040
-
-
-
235
-
-
-
410
-
-
18
S=Stress which shall be taken 40% of minimum
Fe450
0.25
1.20
0.040
0.040
-
-
-
275
-
-
-
450
-
-
15
40% of minimum specified T.S.
IS:4270
ERW
Fe410
-
-
0.040
0.040
-
-
-
235
-
-
-
410
-
-
15 13 G.L.=5.65√area
Hardness 230HV max
P=280T/D for Fe 410
P=350T/D for Fe 450
Fe450
-
-
0.040
0.040
-
-
-
275
-
-
-
450
-
-
Maximum pressure applied shall be 7 Mpa
API
ERW
H40
-
-
0.030
0.030
-
-
40,000
276
80,000
552
60,000
414
-
e=625,000 A°.2/U°.9
27L/20T 20L/15T L=longtitudinal T=Transverse
P=2(fxypxT)/D f= A factor 0.8<10-3/4, 0.6>=10-3/4 yp=specified yield strength(PSI)
5CT
-
J-55
-
-
0.030
0.030
-
-
55,000
379
80,000
552
75,000
517
-
-
NOTE : Refer current editions of Relavant Specification for Dimensions and Properties data
*Specifications are subjected to change without any prior data